Research on Pulse Wave Velocity Measurement Method Based on Dual-mode Algorithm
LIU Cong LIU Yunqing
(School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China)
(Institute of Space Optical Electronic Technology, Changchun University of Science and Technology, Changchun 130022, China)
Abstract:Human Pulse Wave Velocity (PWV) is considered to be one of the important factors that reflects the cardiovascular and cerebrovascular health and the elasticity change of vascular wall. The research of medical pulse wave velocity becomes increasingly hot, such as diabetes, high blood pressure, coronary heart disease, atherosclerosis and other diseases are also closely related. Therefore, the detection of PWV has important and special significance. This paper focuses on signal extraction and signal analysis to study the pulse wave, using the standard clock signal to insert the signal extracted between the brachial artery and radial artery and the dual-mode algorithm of the average among the phase difference of multi-point pulse wave signal, then the PWV is accurately calculated, and its standard deviation is between 0.06 and 0.12. The dual-mode algorithm is superior to the traditional PWV measurement method in real-time, measurement accuracy and stability. It can be used in pulse wave medical research and experiments.
刘聪, 刘云清. 基于双模算法的脉搏波速度测量方法研究[J]. 电子与信息学报, 2018, 40(4): 964-970.
LIU Cong, LIU Yunqing. Research on Pulse Wave Velocity Measurement Method Based on Dual-mode Algorithm. JEIT, 2018, 40(4): 964-970.
SAITO M, MATSUKAWA M, ASADA T, et al. Noninvasive assessment of arterial stiffness by pulse wave analysis[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012, 59(11): 2411-2419. doi: 10.1109/ TUFFC.2012.2473.
[2]
JANA Hruskova, EVA Zavodna, JIRI Moudr, et al. Calculation of the pulse wave velocity from the waveform of the central aortic pressure pulse in young adults[C]. 2015 Computing in Cardiology Conference (CinC), Nice, France, 2015: 385-388.
[3]
KHANDOKER A H, LUTHRA V, ABOUALLABAN Y, et al. Reduced variability in pulse wave velocity in depressed patients with suicidal ideation[C]. 2015 Computing in Cardiology Conference (CinC), Nice, France, 2015: 1061-1064.
[4]
SEO J, PIETRANGLEO S J, and LEE H S. Noninvasive arterial blood pressure waveform monitoring using two-element ultrasound system[J]. IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society, 2015, 62(4): 776-784. doi: 10.1109/TUFFC.2014.006904.
[5]
YANG Xianglin, HU Wei, YAN Hong, et al. Research progress of noninvasive continuous blood pressure measurements based on pulse wave velocity[J]. Space Medicine & Medical Engineering, 2011, 24(6): 467-472. doi: 10.16289/j.cnki.1002-0837.2001.06.010.
[6]
MOHAMMAD Kachuee, MOHAMMAD Mahdi Kiani, HODA Mohammadzade, et al. Cuffless blood pressure estimation algorithms for continuous health-care monitoring [J]. IEEE Transactions on Biomedical Engineering, 2017, 64(4): 859-869. doi: 10.1109/TBME.2016.2580904.
JI Zhong and LIU Xu. Study on feature points recognition of pulse wave based on waveform feature and wavelet[J]. Chinese Journal of Scientific Instrument, 2016, 37(2): 379-386.
[8]
于潇. 基于脉搏波速度的无创连续血压测量系统研究[D]. [硕士论文], 吉林大学, 2013.
YU Xiao. A non-invasive continuous blood pressure measurement system based on pulse wave velocity[D]. [Master dissertation], Jilin University, 2013.
LÜ Haijiao, YAN Zhuangzhi, and LU Weijia. A noninvasive and continuous method for blood pressure measurement using pulse wave[J]. Chinese Journal of Medical Instrumentation, 2011, 35(3): 169-173.
ZHANG Xun and FU Weiwei. Design of dynamic blood pressure measurement system based on pulse wave velocity[J]. Electronic Science and Technology, 2014, 27(1): 63-66. doi: 10.16180/j.cnki.issn1007-7820.2014.01.010.
[11]
NEUMAN M R. Measurement of blood pressure[J] . IEEE Engineering in Medicine and Biology Society, 2011, 2(2): 39-44. doi: 10.1109/MPUL.2011.940568.
LI Zhangjun, WANG Cheng, ZHU Hao, et al. The research progress of non-invasive and continuous blood pressure measurement based on photoplethysmography[J]. Chinese Journal of Biomedical Engineering, 2012, 31(4): 607-614.
LIU Baohua and REN Xiaohua. Research and advance in the measurement of pulse wave velocity[J]. Journal of Biomedical Engineering, 2010, 27(1): 231-235.
LI Mingxia, ZHANG Yongjie, SUN Peipei, et al. New algorithm of calculating feature point of pulse wave velocity [J]. Modern Electronics Technique, 2012, 35(3): 132-134. doi: 10.16652/j.issn.1004-373x.2012.03.019.
LI Shenlong, LI Yibin, LI Hongyang, et al. Non-invasive continuous measurement method of blood pressure based on phase difference of pulse wave[J]. Transducer and Microsystem Technologies, 2016, 35(1): 62-64. doi: 10.13873/ J.1000-9787(2016)01-0062-03.
LIU Baohua, ZHU Honglian, and REN Xiaohua. De-noising and measurement of pulse wave velocity of the wavelet[J]. Journal of Biomedical Engineering, 2011, 28(1): 54-57.
[17]
NABEEL P M, JOSEPH J, AWASTHI V, et al. Single source photoplethysmograph transducer for local pulse wave velocity measurement[C]. 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA, 2016: 4256-4259. doi: 10.1109/ EMBC.2016.7591667.
LI Xiulong. A multi-PWV acquisition method based on peripheral artery waveform analysis[D]. [Master dissertation], University of Science and Technology of China, 2011.