Phase Calibration Method for ATI-SAR System Based on Least Square Estimation and Wavelet-Denoising |
Zhang Huan-sheng①②; Qi Hai-ming①②; Yang Ru-liang① |
①Institute of Electronics, Chinese Academy of Sciences, Beijing 100080, China; ②Graduate University of Chinese Academy of Sciences, Beijing 100039, China |
|
|
Abstract ATI-SAR system requires that the phase characteristic of the two channels is precisely matched. This paper analyzes the phase error of ATI-SAR system, gives the mathematic model, proposes a simple phase calibration method for ATI-SAR system based on Least Square Estimation (LSE) and wavelet-denoising and gives the calibration flow. The simulation results demonstrated that the phase error of ATI-SAR system is removed by this method. This method does require any knowledge of the platform velocity and actual crab angle. The problem of wrapped interferometric phases can be resolved by iterative of this method.
|
Received: 03 November 2005
|
|
|
|
|
|
|
|