The Measurement Uncertainties of Conducted Emission |
Xu Xiao-wen①; Su Dong-lin①; Guo Jun-feng①; Liu Zhi-hang② |
①Bei Hang University, Beijing 100083 , China;
②No.35 Institute of CAST, Beijing 100013, China |
|
|
Abstract Based on the conducted emission measurements for the power line , the measurement uncertainties which affect the Electro Magnetic Compatibility(EMC) test are analyzed. This paper investigates the type A and type B uncertainties and the systemic errors. The results show that the tiny difference of the test setup can bring much difference.
|
Received: 24 January 2005
|
|
|
|
|
|
|
|