DESIGN AND MEASUREMENT OF QUASI-OPTICAL MILLIMETER WAVE SYSTEM FOR PLASMA DIAGNOSTICS |
Shen Xuemin; Wang Zhaoshen |
Institute of Plasma Physics Academia Sinica Hefei |
|
|
Abstract By means of quasi-optical method, the spatial resolving power of millimeter wave receiving system which is used in plasma diagnostics has been greatly improved. In this paper the formulas and procedures for designing a millimeter wave quasi-optical receiving system are presented and some measured results are given.
|
Received: 01 September 1986
|
|
|
|
|
|
|