Abstract:Based on the conducted emission measurements for the power line , the measurement uncertainties which affect the Electro Magnetic Compatibility(EMC) test are analyzed. This paper investigates the type A and type B uncertainties and the systemic errors. The results show that the tiny difference of the test setup can bring much difference.