Abstract:Magnetic Induction Tomography (MIT) is a contactless Electrical Impedance Tomography (EIT) technique to reconstruct the conductivity distribution of biological tissue using the principle of electromagnetic induction. In this paper, a rotating magnetic induction imaging system is constructed by using Helmholtz coil and 20 detection coils, with filtered back projection algorithm. The single target and double target detection coil measurement data are processed by the two order and four order derivative peak sharpening algorithm. The measurement data before and after processing of the reconstructed image are compared by three objective parameters. The results show that the magnetic induction imaging derivative method can effectively increase the peak sharpening image quality.
DIJKSTRA A M, BROWN B H, LEATHARD A D, et al. Clinical applications of electrical impedance tomography[J]. Journal of Medical Engineering & Technology, 1993, 17(3): 89-98. doi: 10.3109/03091909309016213.
[2]
DJAJAPUTRA D. Electrical impedance tomography: Methods, history and applications[J]. Medical Physics, 2005, 32(8): 2730-2731. doi: 10.1118/1.1995712.
[3]
GRIFFITHS H, STEWART W R, and GOUGH W. Magnetic induction tomography: A measuring system for biological tissues[J]. Annals of the New York Academy of Sciences, 1999, 873(1): 335-345. doi: 10.1111/j.1749-6632.1999.tb09481.x.
[4]
GRIFFITHS H. Magnetic induction tomography[J]. Measurement Science and Technology, 2001, 12(8): 1126-1131. doi: 10.1088/0957-0233/12/8/319.
XUAN Yang, WANG Xu, LIU Cheng’an, et al. Incomplete cholesky conjugate gradient method for the three- dimensional forward problem in magnetic induction tomography using finite element method[J]. Journal of Electronics & Information Technology, 2016, 38(1): 187-194. doi: 10.11999/JEIT150437.
LIU Runsheng, DONG Xiuzhen, and LIU Ruigang. Simulation study of linear Kalman filtering algorithm in magnetic induction tomography[J]. Chinese Medical Equipment Journal, 2016, 37(1): 1-4. doi: 10.7687/J. ISSN1003-8868.2016.01.001.
[7]
MARMUGI L and RENZONI F. Optical magnetic induction tomography of the heart[J]. Scientific Reports, 2016, 6: 23962. doi: 10.1038/srep23962.
[8]
YAN Qingguang, JIN Gui, QIN Mingxin, et al. Experimental study on the detection of rabbit intracranial hemorrhage using four coil structures based on magnetic induction phase shift[J]. Biomedizinische Technik Biomedical Engineering, 2017, 62(1): 1-14. doi: 10.1515/bmt-2015-0129.
[9]
LUO Haijun, HE Wei, XU Zheng, et al. Preliminary results on brain monitoring of meningitis using 16 channels magnetic nduction tomography measurement system[J]. Progress in Electromagnetics Research M, 2012, 24(3): 57-68. doi: 10.2528/PIERM12021406.
[10]
GENCER N G, KUZUOGLU M, and IDER Y Z. Electrical impedance tomography using induced currents[J]. IEEE Transactions on Medical Imaging, 1994, 13(2): 338-350. doi: 10.1109/42.293927.
LUO Haijun, HE Wei, XU Zheng, et al. Study on single channel magnetic induction tomography technique based on synchronous detection[J]. Chinese Journal of Scientific Instrument, 2012, 33(4): 899-904. doi: 10.3969/j.issn.0254- 3087.2012.04.027.
[12]
MA Lu and SOLEIMANI M. Magnetic induction tomography methods and applications: A review[J]. Measurement Science and Technology, 2017, 28(7): 072001. doi: 10.1088/1361-6501/aa7107.
LÜ Yi, WANG Xu, YANG Dan, et al. A new measurement method of eddy current for biological tissue in magnetic induction tomography[J]. Journal of Electronics & Information Technology, 2011, 33(9): 2258-2262. doi: 10.3724/SP.J.1146.2010.01422.
[14]
SOLEIMANI M and LIONHEAT W R B. Absolute conductivity reconstruction in magnetic induction tomography using a nonlinear method[J]. IEEE Transactions on Medical Imaging, 2006, 25(12): 1521-1530. doi: 10.1109/ TMI.2006.884196.
WANG Cong, LIU Ruigang, LI Ye, et al. Image reconstruction algorithm for magnetic induction tomography [J]. Chinese Journal of Scientific Instrument, 2008, 29(10): 2052-2057. doi: 10.3321/j.issn:0254-3087.2008.10.007.
[16]
THOMAS C O. A pragmatic introduction to signal processing: With applications in scientific measurement[OL]. https://terpconnect.umd.edu/~toh/spectrum/ResolutionEnhancement.html, 2015.
KE Li, LIU Huan, DU Qiang, et al. Study on iterative reconstruction algorithm for brain magnetic induction based on filtered back-projection[J]. Chinese Journal of Scientific Instrument, 2016, 31(11): 2445-2451. doi: 10.3969/j.issn. 0254-3087.2016.11.005.
LI Bing, HE Wei, HE Chuanhong, et al. Simulation analysis on stimulation patterns of three-dimension electrical imped- ance tomography[J]. Journal of Chongqing University, 2012, 35(2): 78-86. doi: 10.11835/j.issn.1000-582X.2012.02.013.